Câbles hautes températures  

Tri-rated Cable

Tri-rated Cable

Application:
High temperature, flame retardant cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Normes:
BS6231 Type CK
UL Subj.758
CSA c.22.2 No. 127 (only applicable for sizes up to 120mm²)
Chef d'orchestre:
Class 5 flexible plain copper conductors to BS EN 60228:2005 (previously BS6360)
Isolation:
PVC (Polyvinyl Chloride)
Couleur de gaine:
Black, Red, Blue, Yellow, Green/Yellow, Grey,Brown, Orange, White, Violet, Green, Pink, Light Blue, Dark Blue
Tension:
BS6231: 600/1000V
UL, CSA: 600V
Temperature Rating:
BS6231: 90°C (105°C for 15,000 hours)
UL, CSA: 105°C
Minimum Bending Radius:
6 x overall diameter
Note:
Cables above 120mm² in size are referred to as Bi-rated since the CSA standard applies only to sizes up to and including 120mm²

Spécifications de données

Tri-rated Cable

Nombre de Cores
x Nominal
Cross Sectional
Area# x mm²

AWG

Épaisseur nominale d'isolement mm

Diamètre Overall nominal mm

Poids nominal kg/Km

UL Style
Number

1 x 0.50

22

0.80

2.55

12

1015

1 x 0.75

20

1.14

2.55

15

1015

1 x 1.00

18

1.52

2.95

18

1015

1 x 1.50

16

0.80

3.20

23

1015

1 x 2.50

14

0.80

3.65

34

1015

1 x 4.00

12

0.80

4.20

48

1015

1 x 6.00

10

0.80

4.70

67

1015

1 x 10.00

8

1.14

6.50

119

1028

1 x 16.00

6

1.52

8.00

187

1283

1 x 25.00

4

1.52

9.40

291

1283

1 x 35.00

2

1.52

10.60

406

1283

1 x 50.00

1

2.02

12.90

580

1284

1 x 70.00

2/0

2.02

14.60

780

1284

1 x 95.00

3/0

2.02

16.10

1055

1284

1 x 120.00

4/0

2.02

17.90

1175

1284

1 x 150.00

250 MCM

2.41

20.20

1425

1284

1 x 185.00

350 MCM

2.41

22.85

1735

1284

1 x 240.00

450 MCM

2.41

24.40

2310